meta data for this page
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| gallery:start [2026/03/11 00:18] – [Interferometer Experiment for measuring STM piezo displacement (2026-01-18)] rahix | gallery:start [2026/04/26 13:30] (current) – [Picture Gallery] rahix | ||
|---|---|---|---|
| Line 2: | Line 2: | ||
| Various pictures taken at FAFO :) | Various pictures taken at FAFO :) | ||
| + | ==== Evaporation Coated 3D-Print (2026-04-25) ==== | ||
| + | {{: | ||
| + | |||
| + | We used out [[equipment: | ||
| + | |||
| + | ==== Amogus Wafer (2026-04-12) ==== | ||
| + | {{: | ||
| + | |||
| + | Lift-off process for coating an [[https:// | ||
| + | ==== New (Old) Coating Systems (2026-03-30) ==== | ||
| + | {{: | ||
| + | |||
| + | {{: | ||
| + | |||
| + | We managed to acquire these very nice Edwards coating systems for sputtering, thermal evaporation, | ||
| ==== Interferometer Experiment for measuring STM piezo displacement (2026-01-18) ==== | ==== Interferometer Experiment for measuring STM piezo displacement (2026-01-18) ==== | ||
| {{: | {{: | ||
| Line 17: | Line 32: | ||
| See [[https:// | See [[https:// | ||
| + | |||
| + | ==== Work-in-progress wet lab (2025-11-09) ==== | ||
| + | {{: | ||
| + | |||
| + | We managed to get our hands on some high-quality lab furniture. | ||
| + | |||
| + | ==== Random Interconnect Sample (2025-08-23) ==== | ||
| + | {{: | ||
| + | |||
| + | Local interconnect layer of standard cell rows on one of our badly decapped samples. | ||
| ==== Scanning Tunneling Microscope (2025-06-15) ==== | ==== Scanning Tunneling Microscope (2025-06-15) ==== | ||
| Line 27: | Line 52: | ||
| The strucures of the chip are in pretty bad shape from the sanding, but the marking and copyright year are clearly visible. | The strucures of the chip are in pretty bad shape from the sanding, but the marking and copyright year are clearly visible. | ||
| - | Photo was taken using our [[equipment: | + | Photo was taken using our [[equipment: |
| + | |||
| + | ==== Fractured chip (2025-03-18) ==== | ||
| + | {{: | ||
| + | |||
| + | Fracture of a bare silicon die where the individual layers of the chip become visible. | ||
| + | |||
| + | ==== Hello World Zeiss (2025-02-10) ==== | ||
| + | {{: | ||
| + | |||
| + | Our second SEM, [[equipment: | ||
| + | |||
| + | ==== Gardena to KF 16 (2024-10-29) ==== | ||
| + | {{: | ||
| + | |||
| + | Our first big FAFO innovation: A gardena to KF 16 high vacuum adapter. | ||
| ==== OSHW logo on a die (2024-10-10) ==== | ==== OSHW logo on a die (2024-10-10) ==== | ||
| {{: | {{: | ||
| - | The open source hardware (OSHW) logo photographed on a bare die using our [[equipment: | + | The open source hardware (OSHW) logo photographed on a bare die using our [[equipment: |
| ==== Valve assembly of a JEOL JSM-T330A (2024-07-31) ==== | ==== Valve assembly of a JEOL JSM-T330A (2024-07-31) ==== | ||
| {{: | {{: | ||
| - | The valve block of our [[equipment: | + | The valve block of our [[equipment: |
| * The PCB on the left is the vacuum control board, sporting a Z80 microcontroller. This board is mysteriously undocumented so we largely reverse-engineered it here: | * The PCB on the left is the vacuum control board, sporting a Z80 microcontroller. This board is mysteriously undocumented so we largely reverse-engineered it here: | ||
| Line 45: | Line 85: | ||
| * On the right, the back side of the sample chamber is visible. | * On the right, the back side of the sample chamber is visible. | ||
| * In front of the left valve block, two linear regulators are bolted to a metal plate. | * In front of the left valve block, two linear regulators are bolted to a metal plate. | ||
| + | |||
| + | ==== Hello World JEOL JSM-T330A (2024-07-31) ==== | ||
| + | {{: | ||
| + | |||
| + | Our first SEM: [[equipment: | ||