What's still a bit unclear is how there can be situations like in the image above where tunneling stops again as the Z piezo moves even closer? | What's still a bit unclear is how there can be situations like in the image above where tunneling stops again as the Z piezo moves even closer? | ||
+ | |||
+ | Part of a very stable tunneling over a very long period today: | ||
+ | |||
+ | {{: | ||
+ | |||
+ | During mechanical adjustment, the controller now sweeps until it finds something (left side of the picture below). | ||
+ | |||
+ | {{: | ||
+ | |||
+ | Settings during the experiments above: | ||
+ | |||
+ | * '' | ||
+ | * '' | ||
+ | * '' | ||
+ | * '' | ||
+ | |||
+ | Now changing the settings somewhat in hopes of getting the control loop more tight: | ||
+ | |||
+ | * '' | ||
+ | * '' | ||
+ | * '' | ||
+ | * '' | ||
+ | |||
+ | You can see the faster I-response at least: | ||
+ | |||
+ | {{: | ||
+ | |||
+ | It seems the noise has increased since yesterday. | ||
+ | |||
+ | After some time, the control loop settled down quite a bit, assumingly because process disturbances decreased for some unknown reason: | ||
+ | |||
+ | {{: | ||
+ | {{: | ||
+ | {{: | ||
+ | |||
+ | Managed to increase the setpoint current to 456pA: | ||
+ | |||
+ | {{: | ||
+ | |||
+ | Finally tried putting the lid onto the STM for noise shielding, but I think I crashed the tip way too hard during the process as I couldn' | ||
+ | |||
+ | Should create a new tip next time and then retry more gently. | ||