- | === Mechanics | + | === STM Scanning Head === |
+ | The scanning head of our STM uses 3 piezo actuators oriented along the 3 cartesian axes. We currently do not have data on their actuation range. | ||
- | == STM Stage == | + | The tip is made from tungsten wire and mounted to the scanning head using a screw terminal. |
- | The STM stage consists of two aluminum plates which seat against each other precisely using a [[http:// | + | To be documented. |
- | The tip/probe is mounted slightly in front of two of the screws with the last one sitting very far back. This makes the design | + | === STM Mount === |
+ | The STM mount consists of two aluminum plates which seat against each other precisely using a [[http:// | ||
+ | |||
+ | The tip/probe is mounted slightly in front of two of the screws with the last one sitting very far back. This makes a fulcrum | ||
Thread pitch of micrometer screws (according to lab book 16.3.2012): | Thread pitch of micrometer screws (according to lab book 16.3.2012): | ||
Line 27: | Line 31: | ||
* Back is hence 0.0125mm per revolution or 12.5µm | * Back is hence 0.0125mm per revolution or 12.5µm | ||
- | == Vibration | + | === Electronics === |
+ | The control loop for running the STM in constant current mode is currently an entirely analog design. | ||
+ | |||
+ | Learn more about the electronics here: [[https:// | ||
+ | |||
+ | === Vibration | ||
We have built ourselves a simple passive vibration isolation using tension springs and a large mass. The intended damping element (an eddy current brake) did not end up working, but also wasn't really needed after all. | We have built ourselves a simple passive vibration isolation using tension springs and a large mass. The intended damping element (an eddy current brake) did not end up working, but also wasn't really needed after all. | ||
+ | |||
+ | {{: | ||
We have not measured performance, | We have not measured performance, | ||
{{: | {{: | ||
- | |||
- | === Electronics === | ||
- | |||
- | |||
- | |||
- | == Piezos == | ||
- | |||
- | |||
==== Other Projects ==== | ==== Other Projects ==== | ||
There are quite a few other DIY/open STM builds out there. | There are quite a few other DIY/open STM builds out there. | ||
Line 47: | Line 50: | ||
* [[https:// | * [[https:// | ||
* [[https:// | * [[https:// | ||
+ | * [[https:// | ||
+ | * [[http:// | ||
* [[https:// | * [[https:// | ||
* [[https:// | * [[https:// |