 +==== 2026-10-03 (rahix) ====
 +Didn't fix the homing yet, so when we tried homing again today, the micro-manipulator disassembled itself again.
 +
 +Had to rerun axis calibration and it took a few attempts before all axes homed and then started moving successfully.
 +
 +Sequence of G-codes that will most likely get you a working setup at this point:
 +
 +<code>
 +M56 J0 (calibrating X) (ideally watch the curves to see if it looks mostly linear)
 +M56 J1 (calibrating Y)
 +M56 J2 (calibrating Z)
 +G28 (homing all axes)
 +G0 X0
 +G0 Y0
 +G0 Z0
 +</code>
 +
 +If any of the axes don't move to the 0 position (center) with the relevant G0 command, you may have to try again. If all else fails, power-cycle the microcontroller...
 ==== 2026-09-27 (anuejn, rahix) ==== ==== 2026-09-27 (anuejn, rahix) ====
 Now pivoting to using the micro-manipulator for a laser fiber alignment. See [[..:optics:log#day_2026-09-27_anuejn_rahix|Optics Lab Notes 2026-09-27]] for more :) Now pivoting to using the micro-manipulator for a laser fiber alignment. See [[..:optics:log#day_2026-09-27_anuejn_rahix|Optics Lab Notes 2026-09-27]] for more :)
Line 29: Line 47:
  
 The upstream design uses a 2x8mm steel pin. Our FAFO-joints with the pulleys currently lack the respective bore for them. The upstream design uses a 2x8mm steel pin. Our FAFO-joints with the pulleys currently lack the respective bore for them.
 +
 +Additionally, our initial homing direction was correct; reversing the motors would not have been necessary with this homing approach.